Kapasitor Daya Tegangan Tinggi BAM
Aplikasi lan Standar:
Kapasitor tegangan dhuwur utamane digunakake ing sistem Daya AC kanthi 50Hz kanggo nambah faktor daya. Kinerja kasebut cocog karo GB 3083.2-89 《Kapasitor shunt tegangan dhuwur》 lan IEC60871-1987.
GB/T11024-2010 Standar Nasional 《Tegangan voltase 1kV utawa ndhuwur kapasitor shunt kanggo sistem daya AC
Standar Industri Mesin JB/7112-2000 《Kapasitor Shunt HV Dirakit
Standar Industri Tenaga Listrik DL/T628-1997 《Persyaratan Teknis Pemesanan Kapasitor Shunt HV》
Ketentuan panggunaan:
1. Altitude: kurang saka 1000m; Suhu sekitar: -40 ℃ ~ + 40 ℃.
2. Ora ana getaran mekanik sing kasar, ora ana gas lan uap sing mbebayani, ora ana listrik, lan bledug, lan bledug ing lokasi.
3.Tegangan operasi terus-terusan: 1,00 Un, long-term max, Swara voltase: less.1 Un.
4.Stabil liwat-saiki (kalebu harmonics saiki) kurang 1,3 Ing.
5. Kanthi voltase ngadeg: antarane terminal 2.15, wektu dirating voltase kanggo 10 detik, antarane terminal lan wadhah 42kV kanggo 10 detik.
Karakteristik teknis utama:
1. Rated voltase: 6.3kV, 6.6kV, 6.6/√3kV, 7.96kV, 10.5kV, 11kV, 11kV, 11/√3kV, please dituduhake ing urutan yen sampeyan pengin kapasitas khusus liyane.
2.Rated kapasitas: 33~334kvar please dituduhake ing urutan yen sampeyan pengin kapasitas khusus liyane.
3. Kapasitas toleransi: -5 ~ 15%.
4. Loss angel nilai tangensial: film & papaer medium tg θ≦0.08%, film medium tg θ≦0.05%.
5.Withstand voltase: iku bisa saged AC2.15 utawa DC4.3 kaping dirating voltase antarane pales kapasitas, pungkasan bab 10s tanpa break utawa lampu kilat, BIL: 6kV(30kV), 10kV(42Kv).
6. Free discharge: wis resistance utama, 10min sawise Cut mati sumber daya, voltase ampas bakal suda kanggo 75V saka √2 Un.
7. Maks. Saiki: mlaku kanthi lancar ing voltase dirating wektu 1.3, voltase luwih, toleransi positif kapasitas lan gelombang harmonik sing ora bisa ngluwihi 1 menit saben 24 jam.
8.Max.Current: mlaku lancar ing 1.3 wektu dirating voltase, liwat voltase, kapasitas toleransi positif lan gelombang harmonik kang ora bisa 1,43 wektu dirating saiki.
9. Standar: GB / T 112024.1-2001, IEC6087:1997.
KAPASITOR POWER FASE SEPERATE
Model BAM | Tegangan Rated (kV) | Rated Output (kVAr) | Kapasitansi Rated (uF) | Dirating Saiki Ing (A) |
6.3-25-1W | 6.3 | 25 | 2.006 | 3.968 |
6.3-30-1W | 6.3 | 30 | 2.406 | 4.762 |
6.6/√3-25-1W | 6.6/√3 | 25 | 5.481 | 6.561 |
6.3/√3-30-1W | 6.6/√3 | 30 | 6.577 | 7.873 |
6.3/√3-50-1W | 6.6/√3 | 50 | 10.96 | 13.12 |
10.5-25-1W | 10.5 | 25 | 0.722 | 2.38 |
10.5-30-1W | 10.5 | 30 | 0.886 | 2.857 |
10.5-50-1W | 10.5 | 50 | 1.444 | 4.762 |
11/√3-30-1W | 11/√3 | 30 | 2.368 | 4.724 |
11/√3-50-1W | 11/√3 | 50 | 3.946 | 7.873 |
6.3-30-1W | 6.3 | 30 | 2.4 | 4.76 |
6.3-50-1W | 6.3 | 50 | 4 | 7.9 |
6.3-100-1W | 6.3 | 100 | 8 | 15.9 |
6.3-200-1W | 6.3 | 200 | 16 | 31.7 |
6.3-300-1W | 6.3 | 300 | patlikur | 47.6 |
6.3-334-1W | 6.3 | 334 | 26.8 | 53 |
10.5-50-1W | 10.5 | 50 | 1.44 | 4.8 |
10.5-100-1W | 10.5 | 100 | 2.9 | 9.5 |
10.5-150-1W | 10.5 | 150 | 4.3 | 14.3 |
10.5-200-1W | 10.5 | 200 | 5.8 | 19 |
10.5-300-1W | 10.5 | 300 | 8.67 | 28.6 |
10.5-334-1W | 10.5 | 334 | 9.65 | 31.8 |
11/√3-50-1W | 11/√3 | 50 | 3.95 | 7.87 |
11/√3-100-1W | 11/√3 | 100 | 7.89 | 15.75 |
11/√3-150-1W | 11/√3 | 150 | 11.84 | 23.6 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-300-1W | 11/√3 | 300 | 23.68 | 47.2 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
6.6/√3-50-1W | 6.6/√3 | 50 | 10.96 | 13.12 |
6.6/√3-100-1W | 6.6/√3 | 100 | 21.9 | 26.24 |
6.6/√3-150-1W | 6.6/√3 | 150 | 32.9 | 39.36 |
6.6/√3-200-1W | 6.6/√3 | 200 | 43.8 | 52.48 |
6.6/√3-300-1W | 6.6/√3 | 300 | 65.8 | 78.7 |
6.6/√3-334-1W | 6.6/√3 | 334 | 73.2 | 87.6 |
11-100-1W | 11 | 100 | 2.63 | 9.1 |
11-150-1W | 11 | 150 | 3.95 | 13.6 |
11-200-1W | 11 | 200 | 5.26 | 18.2 |
11-300-1W | 11 | 300 | 7.89 | 27.3 |
11-334-1W | 11 | 334 | 8.79 | 30.4 |
12-100-1W | 12 | 100 | 2.2 | 8.33 |
12-150-1W | 12 | 150 | 3.3 | 12.5 |
12-200-1W | 12 | 200 | 4.4 | 16.7 |
12-300-1W | 12 | 300 | 6.64 | 25 |
12-334-1W | 12 | 334 | 7.39 | 27.8 |
12/√3-100-1W | 12/√3 | 100 | 6.63 | 14.4 |
12/√3-150-1W | 12/√3 | 150 | 9.95 | 21.7 |
12/√3-200-1W | 12/√3 | 200 | 13.3 | 28.9 |
12/√3-300-1W | 12/√3 | 300 | 19.9 | 43.3 |
12/√3-334-1W | 12/√3 | 334 | 22.1 | 48.2 |
12/√3-400-1W | 12/√3 | 400 | 26.54 | 57.74 |
6.3-100-1W | 6.3 | 100 | 8 | 15.9 |
6.3-150-1W | 6.3 | 150 | 12 | 23.8 |
6.3-200-1W | 6.3 | 200 | 16 | 31.7 |
6.3-300-1W | 6.3 | 300 | patlikur | 47.6 |
6.3-334-1W | 6.3 | 334 | 26.8 | 53 |
6.6-100-1W | 6.6 | 100 | 7.3 | 15.2 |
6.6-150-1W | 6.6 | 150 | 11 | 22.7 |
6.6-200-1W | 6.6 | 200 | 14.6 | 30.3 |
6.6-300-1W | 6.6 | 300 | rong puluh loro | 45.5 |
6.6-334-1W | 6.6 | 334 | 24.4 | 50.6 |
6.6/√3-100-1W | 6.6/√3 | 100 | 21.9 | 26.24 |
6.6/√3-150-1W | 6.6/√3 | 150 | 32.9 | 39.36 |
6.6/√3-200-1W | 6.6/√3 | 200 | 43.8 | 52.48 |
6.6/√3-300-1W | 6.6/√3 | 300 | 65.8 | 78.7 |
6.6/√3-334-1W | 6.6/√3 | 334 | 73.2 | 87.6 |
11/√3-100-1W | 11/√3 | 100 | 7.89 | 15.75 |
11/√3-150-1W | 11/√3 | 150 | 11.84 | 23.6 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-300-1W | 11/√3 | 300 | 23.68 | 47.2 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
11-100-1W | 11 | 100 | 2.63 | 5.25 |
11-150-1W | 11 | 150 | 3.95 | 7.87 |
11-200-1W | 11 | 200 | 5.26 | 10.5 |
11-300-1W | 11 | 300 | 7.9 | 15.75 |
11-100-1W | 11 | 100 | 2.63 | 5.25 |
11-150-1W | 11 | 150 | 3.95 | 7.87 |
11-200-1W | 11 | 200 | 5.26 | 10.5 |
11-300-1W | 11 | 300 | 7.9 | 15.75 |
12-100-1W | 12 | 100 | 2.2 | 4.8 |
12-150-1W | 12 | 150 | 3.3 | 7.2 |
12-200-1W | 12 | 200 | 4.4 | 9.6 |
12-300-1W | 12 | 300 | 6.64 | 14.45 |
12-100-1W | 12 | 100 | 2.2 | 4.8 |
12-150-1W | 12 | 150 | 3.2 | 7.2 |
12-200-1W | 12 | 200 | 4.4 | 9.6 |
12-300-1W | 12 | 300 | 6.64 | 14.45 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
12/√3-200-1W | 12/√3 | 200 | 13.3 | 28.9 |
12/√3-334-1W | 12/√3 | 334 | 22.1 | 48.2 |
12-200-1W | 12 | 200 | 4.4 | 16.7 |
12-334-1W | 12 | 334 | 7.39 | 27.8 |
10.5-200-1W | 10.5 | 200 | 5.8 | 19 |
10.5-334-1W | 10.5 | 334 | 9.65 | 31.8 |